Fire Extinguisher Valve Custom

Home / Product / Fire Extinguisher Valve
Go back

Custom Fire Extinguisher Valve Manufacturers

Fire Extinguisher Valve is an important component widely used in various types of fire extinguishers and fire extinguishing systems. As key control devices, valves play a vital role in handling fire emergencies. Our valve products have not only passed the EU CE certification, but also obtained ISO9001 quality system certification, providing customers with a guarantee of high quality and reliability. We are committed to designing and producing products that comply with industry standards to meet our customers' needs and expectations.
Our fire extinguisher valve products feature flexible designs and can be customized to meet customers' specific requirements. Whether it is the adaptation of different fire extinguisher models or the needs of specific fire extinguishing systems, we can provide customized solutions. Secondly, our valves have reliable performance and stable operation. Whether in high temperature, high pressure environments or during long-term use, our valves can maintain good working condition and ensure the normal operation of the fire extinguishing system.
In addition, our valve products are easy to install and maintain. With simple installation steps, customers can easily integrate our valves into their fire suppression systems. Moreover, our products are designed with the convenience of routine maintenance in mind, making it easier for customers to inspect and repair valves, thereby minimizing system downtime and maintenance costs.

About Us
Ningbo Kaituo Valve Co., Ltd.
Ningbo Kaituo Valve Co., Ltd., also known as Ningbo Anke Fire Equipment Co., Ltd., is a young and dynamic factory specializing in the research and development, production and export of fire equipment. It owns the anke brand and a number of national high-tech patents.
Founded in 2001, our company is China Fire Extinguisher Valve Factory and Custom Fire Extinguisher Valve Manufacturers, which mainly provides high-quality fire protection products for the international market, specializing in the production of various types of fire extinguisher accessories, marine gas cylinder valves, gas valves, etc. After years of hard work and continuous improvement of process reform, our products are exported to dozens of countries around the world and have won a good international reputation. All of our products have obtained the EU EN, CE certification in 2007.
Welcome all customers to call and visit us. Our company has a professional sales team to provide accurate services.
News
Message Feedback
Fire Extinguisher Valve Industry knowledge

Introduction

  • Fire extinguishers are essential safety devices used to control or extinguish small fires.
  • The valve is a crucial component that regulates the release of the extinguishing agent and ensures reliable performance.
  • This guide provides comprehensive insights into types, maintenance, safety, and selection criteria for fire extinguisher valves.

About Ningbo Kaituo Valve Co., Ltd.
Ningbo Kaituo Valve Co., Ltd., also known as Ningbo Anke Fire Equipment Co., Ltd., is a professional manufacturer specializing in R&D, production, and export of fire protection products, including fire extinguisher valves, marine gas cylinder valves, and other fire safety accessories. Founded in 2001, Kaituo holds multiple national high-tech patents and international certifications (EU EN, CE), offering reliable, high-quality products worldwide.

What is a Fire Extinguisher Valve?

Definition and Function
A fire extinguisher valve is a precision component that controls the release of the extinguishing agent, ensures safety, and maintains pressure integrity.

Key Components

  • Valve Body – The main structure housing the internal mechanism.
  • Handle/Lever – Controls the opening and closing of the valve.
  • Nozzle/Discharge Port – Directs the flow of the extinguishing agent.
  • Safety Pin – Prevents accidental activation.
  • Pressure Gauge (if applicable) – Indicates internal pressure and readiness.

Company Integration
Kaituo valves feature modular construction, precision machining, and corrosion-resistant coatings, simplifying inspection and maintenance while ensuring long-term reliability.

Types of Fire Extinguisher Valves

Based on Extinguishing Agent

Valve Type Suitable Agent Working Pressure (MPa) Discharge Rate (kg/s) Material Kaituo Engineering Feature
Dry Chemical Valve ABC / BC Powder 1.2–1.6 0.7–1.3 Aluminum alloy Wide flow passage design prevents powder blockage
CO₂ Valve Carbon Dioxide 15–21 0.5–1.0 Brass / Stainless Steel Built-in safety relief and anti-freeze handle coating
Foam Valve AFFF / Protein Foam 1.2–1.5 1.2–2.0 Aluminum alloy Corrosion-resistant interior to prevent chemical reaction
Water Mist Valve Water or Water Mist 1.0–1.4 1.5–2.5 Aluminum / Brass Precision nozzle threading ensures fine spray pattern
Clean Agent Valve Halotron, FM-200 1.3–1.8 0.8–1.2 Nickel-plated Brass Leak-proof design prevents agent loss during storage

Based on Operation Mechanism

Valve Type System Type Mechanism Description Kaituo Design Strength
Squeeze Grip Valve Portable Fire Extinguisher Operated manually by squeezing handle and lever Ergonomic lever system reduces actuation force by 15%
Stored Pressure Valve Continuous Pressure System Cylinder remains pre-pressurized; valve controls discharge Precision pressure gauge with anti-vibration seal
Cartridge Operated Valve Industrial / Large Units Separate gas cartridge activates main discharge Modular trigger design simplifies cartridge replacement

How a Fire Extinguisher Valve Works

Step-by-Step Operation

  1. Safety Pin Removal – Unlocks the lever and prevents accidental discharge.
  2. Handle Squeeze – Opens internal port, allowing pressurized agent flow.
  3. Agent Release – Pressurized gas forces agent through the nozzle for extinguishing.
  4. Discharge Control – Releasing the lever reseats the valve.
  5. Pressure Equalization – Residual pressure stabilizes through relief mechanisms.

Pressure and Safety Parameters

Parameter Typical Value Function in Operation Kaituo Advantage
Working Pressure 1.2–2.0 MPa Maintains readiness Precision pressure balancing
Test Pressure 2.5–3.0 MPa Mechanical integrity 100% hydrostatic testing
Burst Pressure ≥4.5 MPa Safety threshold Reinforced body structure
Discharge Time 8–25 s Flow rate control Optimized nozzle geometry
Leakage Rate ≤0.0005 MPa/min Pressure retention Advanced sealing materials

Built-in Safety Mechanisms

Safety Mechanism Function Typical Design Feature Kaituo Implementation
Safety Pin and Seal Prevent accidental activation Metal pin with tamper-evident seal Color-coded safety pins for quick inspection
Pressure Relief Device Releases excess pressure Spring-loaded vent port Integrated relief plug calibrated for 1.5× working pressure
Check Valve System Prevent backflow One-way internal sealing CNC-machined seat for precise fit

Importance of Regular Inspection and Maintenance

Why Regular Inspection is Crucial

  • Detect leaks, corrosion, and mechanical issues early.
  • Ensure pressure stability and operational integrity.
  • Comply with international safety standards.
  • Extend service life of the extinguisher.

Common Problems if Valves Are Not Maintained

Potential Problem Technical Cause Resulting Effect Preventive Measure
Corrosion Moisture, chemical exposure Weak valve Cleaning, corrosion-resistant materials
Leakage Seal degradation Pressure loss Replace O-rings, tighten connections
Clogging Blocked nozzle, powder Reduced flow Clean nozzle and valve channels
Valve Failure Spring/stem fatigue Inoperable discharge Regular testing and lubrication

Fire Extinguisher Valve Inspection Checklist

Visual Inspection for Damage, Rust, or Leaks

Process: Inspect valve body, threads, and O-ring areas for visible damage, corrosion, or deformation.

Inspection Point Acceptable Condition Possible Issue if Defective Kaituo Design Benefit
Valve Body Smooth, no corrosion Pressure loss Anodized/nickel plating
Thread Connection Clean Gas leakage CNC-machined threads
O-Ring Area Flexible Gas leakage High-elasticity O-rings

Pressure Gauge Check

Process: Ensure gauge is within operational range and needle moves smoothly.

Parameter Standard Value Fault Kaituo Quality Feature
Normal Pressure Range 1.2–1.6 MPa Out of range Color-coded scales
Needle Movement Smooth Stuck or vibrating Vibration-dampened mechanism
Gauge Connection Tight Leaks Double-seal structure

Safety Pin Verification

Process: Check pin presence, seal integrity, and orientation.

Parameter Inspection Standard Fault Kaituo Design Characteristic
Pin Material Stainless steel Rust/bend Color-coded, anti-bend
Seal Strength 15–25 N Loose Custom tamper seal tension
Seal Color Bright Faded UV-resistant

Nozzle and Discharge Path

Process: Verify nozzle clearance and unobstructed flow.

Component Check Point Testing Method Kaituo Improvement Feature
Nozzle Orifice Clean Visual/airflow test Anti-blocking geometry
Discharge Hose No cracks Flex test Flexible for repeated bending
Valve Passage Free Low-pressure purge Smooth internal channels

Handle Operation

Process: Test lever smoothness, return spring, and handle integrity.

Inspection Item Acceptable Condition Mechanical Parameter Kaituo Design Advantage
Lever Return Smooth Spring tension 8–12 N Calibrated springs
Stem Movement No sticking Axial clearance ≤0.2 mm Polished stem
Handle Integrity No cracks Static strength ≥300 N Reinforced aluminum

Fire Extinguisher Valve Maintenance

Cleaning

- Clean the valve and nozzle regularly to remove dust, chemical residues, and debris.
- Use neutral cleaning agents that do not react with valve materials or extinguishing agents.
- Kaituo Advantage: Smooth internal channels and anti-blocking geometry reduce residue accumulation and facilitate cleaning.

Lubrication

- Apply lubricants to moving components such as stems and pivot points.
- Use silicone-based or manufacturer-approved lubricants to avoid chemical reactions.
- Kaituo Advantage: Polished stems and calibrated springs reduce friction, ensuring smooth operation even after repeated use.

Testing

- Conduct hydrostatic testing when required to verify pressure integrity.
- Perform functional testing by actuating the valve to confirm smooth operation.
- Kaituo Advantage: Each valve is factory-tested to 1.5× working pressure and calibrated for precise performance.

Replacement

- Identify valves that are leaking, corroded, or mechanically damaged.
- Replace faulty components using Kaituo-certified replacement parts to maintain safety and compatibility.
- Kaituo Advantage: Modular valve designs allow straightforward replacement of O-rings, stems, and gauges.

Common Problems with Fire Extinguisher Valves and Troubleshooting

Leakage

- Common causes: Worn O-rings, loose threads, micro-cracks.
- Kaituo Solution: CNC-machined threads and high-elasticity seals ensure long-term airtightness.

Clogging

- Causes: Powder residue, moisture, improper cleaning.
- Kaituo Solution: Anti-blocking internal geometry and polished passages prevent accumulation.

Hard to Squeeze / Operate

- Causes: Friction, spring fatigue, misalignment.
- Kaituo Solution: Ergonomic handle, polished stems, heat-treated springs.

Corrosion

- Causes: Humidity, chemical exposure.
- Kaituo Solution: Nickel-plated brass, anodized aluminum, multi-layer protective coatings.

Pressure Gauge Inaccuracy

- Causes: Faulty gauge, moisture ingress, wear.
- Kaituo Solution: Factory-calibrated gauges with double-sealed protection.

Safety Precautions When Handling Fire Extinguisher Valves

Depressurizing the Extinguisher Before Maintenance

- Verify cylinder pressure (gauge reads zero).
- Release residual pressure in a controlled manner.
- Confirm no pressure using a test gauge.
- Kaituo valves feature secondary relief grooves for safe depressurization.

Wearing Appropriate Safety Gear

- Dry Chemical: Mask, goggles, gloves.
- CO₂: Thermal gloves, face shield.
- Foam / Water Mist: Rubber gloves, non-slip shoes.
- Clean Agent: Respirator, ventilated space.
- Kaituo Engineering Support: Smooth discharge, insulated handles, corrosion-resistant lining, and precise metering valves.

Avoiding Exposure to Extinguishing Agents

- Dry Powder: Avoid inhalation; ventilate.
- CO₂: Avoid frostbite; insulated horn.
- Foam: Avoid chemical contact.
- Clean Agent: Ensure ventilation.
- Kaituo Safety Design: Controlled release and smooth flow channels.

Proper Disposal of Damaged or Replaced Valves

- Damaged Valve: Render inoperative and recycle.
- Corroded: Remove residue, segregate metal.
- Faulty Gauge: Depressurize before disposal.
- Kaituo Recommendation: Follow eco-safe disposal guidelines.

Choosing the Right Fire Extinguisher Valve

Factors to Consider

Selection Factor Description Kaituo Technical Feature
Type of Agent Valve compatibility Dedicated valve series for powder, CO₂, foam, clean agent
Operating Pressure Defines cylinder pressure Tested to 1.5× rated working pressure
Cylinder Capacity Flow path and stem size Multiple flow diameters DN18–DN50
Material Compatibility Resist corrosion & temperature Aluminum, nickel-plated brass, stainless steel
Operation Type Stored-pressure or cartridge Modular interchangeable design
Maintenance Accessibility Ease of service Threaded modular construction

Comparison by Operation Mechanism

Valve Type System Type Mechanism Description Kaituo Design Strength
Squeeze Grip Portable Manual handle squeeze Ergonomic, reduces force 15%
Stored Pressure Continuous Pre-pressurized cylinder Precision gauge + anti-vibration
Cartridge Operated Industrial Separate gas cartridge triggers Modular, easy replacement

Environmental and Application Considerations

Environment Risk Factor Kaituo Valve Solution
Coastal / Marine High salinity Nickel-plated / stainless steel
Cold (-30°C) Seal hardening Temperature-resistant seals
Industrial Plants Chemical exposure Multi-layer coating
High Humidity Condensation / oxidation Anodized aluminum

Supplier Reliability: Ningbo Kaituo Valve Co., Ltd. is a certified manufacturer with 20+ years of experience, producing valves with ISO 14001 environmental compliance, EU EN / CE certification, and a strong global export reputation.