Fire Hose Cabinets and Reels

-- Steady & Reliable Manufacturer --

Introduction: Organized and Accessible Hose Stations

Fire Hose Cabinets and Reels provide essential, organized storage for manual fire fighting equipment (hose, nozzle, valves) in buildings. These enclosures protect the equipment from environmental damage and tampering while ensuring immediate accessibility for trained occupants or fire department personnel (Fire Brigade Connections). Their design must blend architectural aesthetics with rigorous fire code compliance.

We supply various types: Hose Reels (permanently connected, semi-rigid hose wound on a reel, typically for occupant use), Rack Systems (featuring a folding cotton/polyester attack hose that deploys rapidly for standpipe systems), and Recessed or Surface-Mounted Cabinets (housing both hose and fire extinguishers). Cabinets are typically fabricated from heavy-gauge cold-rolled steel or stainless steel, finished with a high-visibility powder coating or brushed metallic finish.

All units comply with NFPA 14 (Standard for Standpipe and Hose Systems) and local building codes. Cabinets feature clear instructional signage, locking mechanisms (if required), and ample space for the required hose, valve assembly, and, optionally, a fire extinguisher. (Approx. 540 words)

Advantage: Durability, Code Compliance, and Aesthetic Integration

  • NFPA 14 Compliance: Ensures the hose type, length, and cabinet installation meet the mandatory requirements for standpipe and hose systems.
  • Equipment Protection: Cabinets safeguard the hose and nozzle from UV light, dust, and potential vandalism, extending the equipment's lifespan.
  • Quick Deployment: Hose racks and reels are designed for rapid, tangle-free deployment, minimizing critical response time during an emergency.
  • Corrosion Resistance: Stainless steel options and high-quality powder coatings ensure durability in humid or corrosive coastal environments.
  • Aesthetic Flexibility: Available in recessed designs with trim kits to seamlessly integrate into high-end architectural settings.
  • Visibility and Signage: Meets code requirements for clear labeling ("FIRE HOSE") and often includes instructional graphics for proper use.

Specification: Type, Material, and Code Compliance

Hose Station TypeHose Reel, Hose Rack (Standpipe Use), Cabinet (Recessed/Surface)
Cabinet MaterialCold-Rolled Steel, Stainless Steel (Gauge 16 to 20)
Hose Reel Length20 m to 30 m (Semi-Rigid)
Hose Type (Rack)1.5 inch or 2.5 inch Folding Attack Hose
Valve ConnectionAngle Valve (1.5 inch or 2.5 inch NPT/BSP)
Door/LatchFull-length Hinge, Latch (Handle/Break-Glass)
Standard ComplianceNFPA 14, UL/FM Component Listed, Local Building Codes
FinishRed Powder Coated, White Enamel, or Brushed Stainless Steel

Organized Deployment for Building Occupants and Firefighters

Commercial Office Buildings

Recessed cabinets housing 1.5 inch hose racks or reels, typically located near stairwells and standpipe risers for occupant use.

Industrial Facilities and Warehouses

Surface-mounted, heavy-duty cabinets with 2.5 inch hose connections for fire brigade use, ensuring high water flow capability.

High-Rise Residential Towers

Aesthetically designed cabinets that blend into hallways while providing access to the required hose valve (usually requiring a fire department connection).

Parking Garages and Tunnels

NEMA 4X rated (weatherproof) cabinets or enclosures to protect the hose and valve from dust, moisture, and potential vehicle impact.

Hotels and Schools

Easy-to-use hose reels (semi-rigid) that allow trained personnel to quickly unroll and operate the hose station with minimal training.

Grow Your Bussiness With KAITUO

  • INNOVATION

    Professional R&D Team

    We have a professional R&D team of over 15 people who are able to provide innovative products and customized design services to our customers.
  • QUALITY

    Product quality assurance

    We adhere to quality as a lifeline for our business development, and strict quality management systems ISO and CE, as well as a variety of advanced quality testing equipment are our guarantees for product quality.
  • PRODUCTION CAPACITY

    Annual output exceeds 400,000

    Every month over 400,000 pcs of kinds of valves, including fire extinguisher valve, lpg valve, marine gas cylinder valve and so on.
  • SERVICE

    One-stop service

    We have complete design, and product development, testing and quality control are all carried out in the factory, which to a certain extent guarantees the high quality and performance of Kaituo fire equipment.

Payment & Shipping: Flexible Global Trade Solutions

We offer comprehensive and secure international trade terms tailored to our global clientele.

  • Accepted Payment Methods:

    Wire Transfer (T/T): Standard 30% deposit to confirm the order, 70% balance upon presentation of Bill of Lading (B/L) copy.

    Letter of Credit (L/C): Irrevocable L/C at sight for large construction projects, providing maximum financial security for both parties.

  • Shipping Terms (Incoterms):

    FOB (Free On Board): Ningbo Port is our standard shipping hub.

    CIF/CFR: Available upon request; we manage shipping logistics to your designated port.

  • Packaging:

    Cabinets are shipped individually, protected by cardboard and foam inserts, often palletized for bulk orders to prevent dents or damage.

Comprehensive Information Summary

Minimum Order Quantity (MOQ)200 Units (Cabinets), 500 Units (Hose Reels)
Lead Time45-60 Days (Metal Fabrication, Coating, and Assembly)
PackagingIndividual Cartons, Protected Corners, Palletized.
CertificationsNFPA 14 (Compliance), UL/FM Component Listing, ISO 9001.
Raw MaterialsCold-Rolled Steel/Stainless Steel (Cabinet), Brass (Valve/Nozzle), Rubber/Synthetic Fiber (Hose).
Customization OptionsRecessed Depth, Door Style (Full Glass/Solid), Finish Color, Custom Hose Length/Type, Integrated Extinguisher Compartment.

Professional Usage Tips

  1. Accessibility and Clearance:

    Ensure the cabinet is installed at the correct height (NFPA 14) and that the door has a 90∘ swing clearance to allow the hose to be fully deployed without obstruction.

  2. Hose Maintenance:

    The folding hose (rack system) must be removed and visually inspected annually. It should be re-racked with a new fold pattern to prevent permanent creasing and cracking.

  3. Valve Operation Check:

    The angle valve or pressure regulating valve inside the cabinet must be operated (opened/closed) during the annual system inspection to ensure smooth function.

  4. Break-Glass Security:

    If the cabinet uses a break-glass latch, ensure replacement glass and a small hammer (if required by code) are securely stored nearby or within the cabinet.

  5. Pressure Regulation:

    In high-rise buildings, ensure the 2.5 inch hose connection has a functioning Pressure Regulating Valve (PRV) to limit outlet pressure to a maximum of 175 psi (NFPA 14).

Get in Touch

ABOUT KAITUO
Ningbo Kaituo Valve Co., Ltd., also known as Ningbo Anke Fire Equipment Co., Ltd., is China Fire Hose Cabinets and Reels Manufacturers and Wholesale Fire Hose Cabinets and Reels Factory, specializing in the research and development, production and export of fire equipment. It owns the anke brand and a number of national high-tech patents.
Founded in 2001, our company mainly provides high-quality fire protection products for the international market, specializing in the production of various types of fire extinguisher accessories, marine gas cylinder valves, gas valves, etc. After years of hard work and continuous improvement of process reform, our products are exported to dozens of countries around the world and have won a good international reputation. All of our products have obtained the EU EN, CE certification in 2007.
Welcome all customers to call and visit us. Our company has a professional sales team to provide accurate services.
Read More

FAQ

A Hose Reel uses semi-rigid hose for basic occupant use. A Hose Rack uses larger, folding attack hose (1.5 inch or 2.5 inch) for connection to a standpipe system.

They are required in buildings that must have a standpipe system (typically multi-story commercial or high-rise residential) as mandated by NFPA 14.

The small hose reels and racks are typically equipped with a 1 inch or 1.5 inch hose connection.

The 2.5 inch connection is a fire department outlet, designed for use only by trained firefighters who can handle the higher pressure and flow.

The hose assembly must be hydrostatically tested every 5 years (for 1.5 inch single jacket hose) or every 3 years (for 2.5 inch fire department hose), per NFPA 25.

A recessed cabinet is mounted entirely or mostly within the wall, providing a flush, aesthetically pleasing, and less obstructive installation in hallways.

The Minimum Order Quantity (MOQ) for bulk hose cabinets is typically 200 units.

The viewing panel often uses safety glass or acrylic for visibility, with a thin, easily breakable panel or plastic cover used for the latch mechanism.

Class I is 2.5 inch (Fire Dept. use), Class II is 1.5 inch (Occupant use), and Class III provides both 2.5 inch and 1.5 inch connections.

No. While some cabinets are secured, NFPA 14 requires that all cabinets be readily accessible, and if locked, a means of emergency entry (e.g., break glass) must be provided.