Looking for custom fire protection solutions? As an experienced manufacturer and supplier, Ningbo Kaituo Valve Co., Ltd. (ANKE Fire) offers tailored product designs to fit your exact business needs. The 6-9KG Cartridge Fire Extinguisher valve 1046 is a versatile copper valve for compatible 6–9 kg cartridge fire extinguishers. Its M74X2 inlet, M14X1.5 outlet, M15X1.25 gauge connection, and M16X1.5 dip tube thread support a defined range of extinguisher configurations. The simple structure, visible operating markings, and optional plated finish make it suitable for OEM production, replacement supply, and routine maintenance applications.
The 6-9KG Cartridge Fire Extinguisher valve 1046 is designed for 6-9 kg cartridge fire extinguisher assemblies. The source document describes the valve as suitable for different extinguisher models and brands, and mentions potential use with dry powder, water, and foam extinguishing agents. This compatibility should be understood as conditional: the valve must be matched with the correct cylinder, cartridge system, extinguishing agent, pressure rating, and applicable standard.
The valve body is made from high-quality copper. The material is described as offering corrosion and oxidation resistance, helping the valve maintain stable performance in different environments. The internal structure is described as simple, which may support installation, inspection, and replacement of compatible components.
The valve includes clear opening and closing markings, allowing the operator or service technician to identify the operating position more easily. Its pressure gauge interface allows pressure status to be monitored when a compatible gauge is installed.
Product Parameters
Parameter
Specification
Valve Type
6-9KG Cartridge Fire Extinguisher valve
Material
High-quality Copper
Surface treatment
According to customer requirements (chrome/nickel plated)
Inlet thread
M74X2
Outlet thread
M14x1.5
Gauge Connection thread
M15X1.25
Dip tube pipe thread
M16X1.5
Safety Device (Bar)
No
Check Valve
No
Applicable Cylinder
6-9KG Fire Extinguisher
Customization
Thread configuration, surface finish, handle style, and other parameters upon request
A Practical Compatibility Checklist
The 6-9KG Cartridge Fire Extinguisher valve 1046 should be selected by comparing the complete assembly, not just the extinguisher capacity.
Matching item
What the buyer should confirm
Cylinder neck
M74X2 inlet and sealing interface
Discharge connection
M14X1.5 outlet compatibility
Pressure gauge
M15X1.25 gauge connection
Dip tube
M16X1.5 connection and correct length
Cartridge system
Correct gas-release arrangement
Agent
Compatibility with the intended extinguisher design
Pressure
Approved operating and test requirements
The valve can be used with different extinguisher models and brands, but compatibility should still be confirmed by drawing and assembly requirements. A thread match alone does not establish full system compatibility.
Why Choose 1046 for a Cartridge Extinguisher Project?
The 6-9KG Cartridge Fire Extinguisher valve 1046 may be relevant when a buyer needs:
1. A 6–9KG cartridge extinguisher valve.
2. An M74X2 inlet.
3. An M14X1.5 outlet.
4. An M15X1.25 gauge connection.
5. An M16X1.5 dip tube thread.
6. A copper valve with customizable surface treatment.
7. A supplier able to confirm the complete cylinder and cartridge configuration.
Operation and Maintenance
The clear opening and closing markings are useful during routine inspection and emergency operation. The source document also describes a simple internal structure that can facilitate regular inspection and replacement of compatible parts.
Maintenance personnel should inspect:
1. Valve body for corrosion or mechanical damage
2. Operating handle and markings
3. Thread condition
4. Gauge connection for leakage
5. Outlet assembly
6. Dip tube connection
7. Cartridge system compatibility
8. Signs of deformation or wear
Any maintenance, disassembly, or replacement should be performed by qualified personnel following the extinguisher manufacturer’s instructions and applicable regulations.
Environmental Performance
The copper body as having corrosion and oxidation resistance and being suitable for different harsh environments. Actual environmental durability will depend on exposure conditions, storage, cleaning agents, humidity, temperature, and surface treatment. Chrome or nickel plating can be considered when a particular appearance or additional surface protection is required.
FAQ
Q1: What capacity range is model 1046 designed for?
A1: It is specified for 6–9 kg cartridge fire extinguishers.
Q2: What gauge thread does model 1046 use?
A2: The gauge connection is M15X1.25.
Q3: Does model 1046 include a safety device?
A3: The source specification lists no safety device.
Q4: Does it include a check valve?
A4: The source specification lists no check valve.
Q5: How is model 1046 different from model 1041?
A5: Both use an M74X2 inlet and M14X1.5 outlet, but model 1041 is specified for 6–12 kg extinguishers and uses an M18X1.5 gauge connection with a 22–26 bar safety device. Model 1046 is specified for 6–9 kg extinguishers, uses an M15X1.25 gauge connection, and lists no safety device.
Send your inquiry now to Anke Valve China factory. Request factory price, free sample, OEM customized fire extinguisher valve quotation for bulk order purchase.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy